Adjust Vibration Sensitivity

Adjust Vibration Sensitivity

 
The touch/vibration sensitivity has 7 levels to suit the environment the Audible alarm operates within i.e Areas where the host shed/building is subject to increased vibration due to high winds, road works in area may want a lower sensitivity setting than the default high setting). To identify the level of sensitivity during the set up process listen for ‘Dow, Le, Mi, Fa, So, La, Di’ each identifying a different level of sensitivity. 

 

Setting up, Touch/Vibration sensitivity
 
1.      Pre-setting mode. Press and hold the disarm button (2nd down, rectangle, open padlock image), the audible alarm will continually ring the disarming sound (please ignore this disarming sound) . Hold until the remote control light (around the arming button above) turns off,  keep holding until and control light comes back on again, then immediately release the disarm button. The audible alarm will then be ready for Setting up in relation to either the ,Vibration sensitivity, Volume or SOS feature as  below
2.      Sensitivity setting. First ensure you have engaged the pre-setting mode (1 above). To adjust the sensitivity of the vibration setting level, press the arm button (Top circular button, padlock image) in rotation from high to low (‘Dow, Le, Mi, Fa, So, La, Di’) cycle and stop at the desired level of 7 options you require. i.e. Press once for ‘Dow’, most sensitive, Press 7 times for ‘Di’ least sensitive